Skip to content

Mechanical & HVAC Suspension Hangers

Gripple wire cable hangers for the fast suspension of cable containment, pipework, radiant panels and chilled beams.

Gripple’s products are designed to save you time, and labour costs, thus improving the efficiency of your installation. Unlike traditional methods, Gripple kits do not require cutting, filing or “hot works” permits. Gripple suspension solutions offer aesthetic design without compromising on strength; supplied in kits ready for use with a choice of wire rope lengths and end fixings.

Mechanical Applications

Mechanical HVAC Suspension Install Projects

Gripple wire suspension systems offer significant advantages in the installation of all types of heating, ventilation and air conditioning services when compared to traditional ‘clamp and rod’ methods. Gripple’s HVAC solutions ensure you make significant savings in time and labour costs; the flexibility of the system allows suspension of services from any angle, whilst maintaining unyielding support once in place. Making them perfect solutions for mechanical, HVAC, and duct hangers.

Delivered in ready-to-use kits with your choice of wire length and end fixing, there’s no need for tools and time spent working at height is significantly reduced.

  • HVAC
  • Pipework
  • Radiant panels
  • Chilled beams
  • Heating
  • Ventilation
  • Air Conditioning
  • Plus more

Mechanical & HVAC Suspension Products

Complete your project with one of Gripple’s most popular products, view the Mechanical & HVAC Suspension range or contact the Polyplas International Area Manager in your region.

  • Express Hanger
    This product has multiple variants. The options may be chosen on the product page

    Express Hanger

    $1,000.00$10,000.00

Industry Approvals & Certifications

  • AS1170.4 and NZS4219 compliant
  • In accordance with ANSI/ASHRAE 171
  • OSHPD OPA 2123-10
  • UL NEBS GR 63 Core Certification
  • SMACNA Verification
  • International Building Code (IBC)
  • California State Building Code
  • National Fire Protection Association (NFPA)
  • American Society of Civil Engineers (ASCE) 7-05 Chapter 13
  • Unified Facilities Criteria (UFC) 300 and 400
  • American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE)
  • Federal Emergency Management Agency (FEMA)
  • Engineered seismic bracing calculations and details based upon drawings/plans provided
  • PE stamped layout drawings for each service noting the proper location of Gripple Seismic Cable Bracing and/or Vibration Management products (spring mounts, vibration isolation pads, hangers, and accessories), per the scope of the project.

Mechanical & HVAC Suspension Articles

Te Pae Christchurch Convention Centre

Te Pae Christchurch Convention Centre

Project Overview Gripple non-rigid seismic bracing, RIKTA rigid bracing and RIKTA beam clamps were supplied…

Read more
Bank of NZ Offices

Bank of New Zealand

Where: Nationwide throughout New Zealand What: Electrical, Mechanical, Fire, Plumbing, Security Seismic Restraints Project Overview Bank of…

Read more
Back To Top